HOW TO USE
Quick Calibration
For optimum scanning condition, perform the Quick Calibration after replacing the fluorescent
lamp or if dark lines appear in the horizontal direction on the output image.
1.Clean the sheet surface
First, clean a strip about 20 cm (8 inches) wide along the left side of the sheet surface.
Make sure the sheet is completely clean and there are no marker traces left.
* Apply some water to a soft cloth, wring out thoroughly, then wipe the sheet clean. For tough dirt, wipe using
a clean cloth with a solution of diluted neutral detergent, then wipe again with a cloth dampened with water
to remove all traces of the detergent.
2.Start Quick Calibration
1) Turn off the power.
2) Turn on the power while pressing One-page copy key(BF-041S) or A4 size copy key(BF-
041W)
3) It goes into warm-up mode. Both Power lamp and Paper warning lamp blink simultaneously,
and the fluorescent lamp lights. The sheet stays still until the warm-up finishes (approxi-
mately 5 minutes).
4) The sheet automatically moves about 3 blocks of ruled line and calibration is performed.
5) When the Power lamp stays lit, the copyboard is ready for normal operation.
* If both Power lamp and Paper warning lamp keep blinking alternately, please try Quick Calibration again
from the first step.
* Do not start using the copyboard until the sheet has completely dried.